Gap & Flush Measurement

AutoGap & HandyGap

Non-contact gap and flush measurement – fully automatic in the line or handheld.

HandyGap replaces feeler gauges with a handheld device based on laser triangulation. Gap and flush values are calculated in real time, out-of-tolerance values are flagged and all data is stored for traceability. AutoGap fully automates the measurement: robot-guided vision sensors capture the gap pattern inline without contact – on stop-and-go lines as well as on moving lines.

Used in: Body shop · Final assembly · Rework stations

Automatic gap and flush measurement on the car body
±0.05 mm
measurement accuracy
±0.02 mm
repeatability
≤ 0.5 s
per measurement (AutoGap)
0.5–20 mm
gap measuring range, flush 0–20 mm

Video

AutoGap & HandyGap in operation

AutoGap & HandyGap – Gap & Flush Measurement

Benefits

What AutoGap & HandyGap do for your production

01

Mixed-model lines without changeover

The color code from the PLC adjusts exposure automatically; new models require no additional hardware. Offline, on stop-and-go lines and on moving lines.

02

Dual sensor design

Wider laser coverage also captures the inner contour of hemmed gaps; separate exposures ensure image quality on every material and color.

03

Demanding surfaces

Transparent parts such as headlights and high-gloss surfaces are measured reliably.

04

Traceable data

All measured values are stored and available for process optimization.

Applications

The measuring systems cover gap and flush inspection from the body shop to final inspection:

AutoGap sensor measuring the door gap
  • Doors, hoods, fenders and side panels
  • Around the headlights
  • Roof and side frames
  • Closures and outer panels
  • Body shop finish line
  • Final assembly inspection line
  • Rework stations
  • Audit and spot checks

Technical data

AutoGap & HandyGap at a glance

Measurable gap typesHemmed, bevel, sharp-edge, T-type, H-type, parallel and small gaps
measurement accuracy±0.05 mm
repeatability±0.02 mm
Measuring rangeGap 0.5–20 mm, flush 0–20 mm
Measuring timeAutoGap ≤ 0.5 s, HandyGap ≤ 1 s per measurement
LaserBlue-violet (AutoGap)
Operating temperatureAutoGap 0–45 °C, HandyGap 0–50 °C
HandyGap4.3-inch touch screen, wired or wireless, standalone without a PC

Image gallery

Application examples

AutoGap measuring station in final assembly
AutoGap measuring station in final assembly
HandyGap handheld device
HandyGap handheld device
Handheld measurement with HandyGap
Handheld measurement with HandyGap

Check feasibility on your part

Send us the part drawing and inspection requirements. Our application team will provide a well-founded initial assessment.

Send an inquiry